Your old rotation_distance value
Actually extruded mm
Requested mm
Your new
rotation_distance
value is:
How to measure!
With the hotend at temperature, make a mark 100mm and 120mm away from the extruder entrance
In your Webinterface extrude 50mm 2 times at max 2mm/s
Measure the distance from the extruder to the first mark (100mm)
In a perfect world, you would extrude 100mm and land exactly at the first mark.
If you extruded less than 100mm, measure to the 100mm mark. For example, if the distance is 5mm between the extruder and the 100mm mark, you extruded 95mm
If you extruded more than 100mm, measure to the 120mm mark. For example, if the distance is 17mm between the extruder and the 120mm mark, you extruded 103mm
Use the
Calculator
above to calculate the new value